SINE WAVE THREE PHASE INVERTER (ALBS)

Overview

Zunax sine wave Automatic Lift backup System (ALBS) is specifically designed to address the requirements of running lift motors with high torque. These ALBS output 3 phase supply that is similar to the 4 wire mains 3 phase supply and can be effortlessly switched in with a simple electronics changeover in case of power failure to power lifts and elevators. The same ALBS can be used as a power source for staircase, parking, compound and common lighting as well as a power source for security systems. Zunax ALBS features DSP based three phase sine wave output inverter module, battery charger, electronic changeover and extra heavy duty components to handle high starting torque currents drawn by lift motors, pump sets and air conditioners.
Description 6KVA 8KVA 10KVA 12KVA 15KVA 20KVA 25KVA 30KVA 40KVA 70KVA
BACK-UP MODE
BACK-UP MODE Pure Sine Wave
Nominal Battery Voltage 72V DC 180V DC 180V DC 180V DC 180V DC 276V DC 360V DC 360V DC 360V DC
96V DC 360V DC 240V DC 276V DC 360V DC
180V DC 360V DC 360V DC
Output Power Factor 0.8
O/P Voltage (N-L) 230V±2.5V AC
Max. No Load Batt. Current 0.9A±0.2A
Frequency 50Hz±1.0Hz
Total Harmonic Distortion <3%
O/P Voltage (L-L) 400V±2.5V AC
Full Load O/P Current/Phase 8.7A±0.5A 12A±0.5A 14A±0.5A 17A±0.5A 21.5A±0.5A 23.5A±0.5A 29.5A±0.5A 34.9A±0.5A
Low Battery Indication 10.5A±0.2V DC Per Battery (12V DC Each)
MAINS MODE
Input Voltage Range (N-L) 140V to 280V AC±10V AC
Input Voltage Range (N-L) 242V to 484V AC±10V AC
Max. Charging Current 10A±1A
Boost Charging Voltage 14.2V±0.2V DC per Battery (12V DC Each)
Trickle Charging Voltage 13.7V±0.2V DC per Battery (12V DC Each)
FOR THREE PHASE INVERTER
Change over time (Mains to Battery) <=40 millisec
Change over time (Battery to Mains) <=10 millisec
FOR THREE PHASE ALBS
Change over time (Mains to Battery) <=30 millisec
Change over time (Battery to Mains) <=10 millisec
PROTECTIONS
Protections Output not OK, Battery Voltage Low (4 Auto Retries), Over Load (6 Auto Retries)
Battery Over Charge, Over Temperature, Short Circuit, Main MCB Tripped
DISPLAYS
Displays Welcome Message, Capacity, Output Voltage, Output Frequency, Load Percentage
Input Voltage and Frequency, Battery Charging, Battery Voltage, All Protections
ENVIRONMENTAL PARAMETERS
Operating Temperature 0 Deg – 45 Deg
Acoustic Noise at 1 mtr. <45 dB
Relative Humidity Max 95% non-condensing
Thermal Management Integrated cooling (Fan & Heat Sink)
WEIGHT AND DIMENSIONS
With Packaging (LxWxH in mm) 700x500x780 860x630x950 1020x860x1450
Without Packaging (LxWxH in mm) 540x340x660 700x450x840 810x580x1310
Net Weight 85kg 93kg 96kg 106kg 134kg 171kg 212kg 218kg
Gross Weight 96kg 104kg 107kg 117kg 148kg 191kg 232kg 245kg