Sr. No. | System Capacity | 650VA | 850VA | 1050VA | 1450VA | 2000VA | UNIT |
---|---|---|---|---|---|---|---|
1 | Max PV Panel Power 5 | 500 | 1000 | W | |||
2 | Battery Voltage | 12 | 24 | V | |||
3 | No Load Current | <2.2 | A | ||||
4 | Output Voltage @ No Load | 220±7 | V | ||||
5 | Output Voltage @Full Load | 180V-220V | V | ||||
6 | DC Current @ Full Load (Battery Input) | 43A ± 2A | 57A ± 2A | 63A ± 2A | 47A ± 2A | 62A ± 2A | A |
7 | Output Current @ Full Load(AC Side) | 2.3 | 2.8 | 3.7 | 5.3 | 7.2 | A |
8 | Output Frequency | 50 ± 1 | Hz | ||||
9 | Solar Charger Type | PWM | |||||
10 | Min Solar charger Efficiency | 90% | 90% | 90% | 90% | 90% | |
(A) | UPS Mode | ||||||
1 | Grid Input Voltage Range | 180 ~ 260 ± 10 | V | ||||
2 | Change Over Mains to UPS | <=10 | msec | ||||
3 | Change Over UPS to Mains | <=10 | msec | ||||
(B) | Normal Mode | ||||||
1 | Grid Input Voltage Range | 100 ~ 280 ± 10 | V | ||||
2 | Change Over Mains to UPS | <=50 | msec | ||||
3 | Grid Input Voltage Range | 180 ~ 260 ± 10 | V | ||||
4 | Change Over UPS to Mains | <= 10 | msec | ||||
(C) | Charging Mode (HC/QC) | ||||||
1 | Max Charging @ Mains Only | 15 ± 2 | A | ||||
2 | Grid Input Voltage Range | 40 ± 2 | A | ||||
3 | Max Charging @ Solar + Mains | 25 ± 2 | A | ||||
(D) | Charging Mode (NC/EC) | ||||||
1 | Max Charging @ Main Only | 15 ± 2 | A | ||||
2 | Max Charging @ Solar Only | 30 ± 2 | A | ||||
3 | Max Charging @ Solar + Mains | 25 ± 2 | A | ||||
4 | Mains Charging Current will be zero if solar current is > 13A, Max charging current at below 13.7 V Battery voltage,> 13.7 charging current is 15A ± 2A, system will cut off the mains when battery is charged and Output load transferred to Solar + Battery Power.while charging from Grid + Solar, Solar remains in priority taking minimum current from Grid. | ||||||
(E) | Battery Charging Voltage | ||||||
1 | Boost Voltage | 14.4 ± 0.2 | 28.8 ± 0.2 | 28.8 ± 0.2 | V | ||
2 | Float Voltage | 13.7 ± 0.2 | 27.4 ± 0.2 | 27.4 ± 0.2 | V | ||
(F) | Protection | ||||||
1 | Over Load Warning | Yes | Yes | Yes | Yes | Yes | Display |
2 | Over Load Protection | Yes | Yes | Yes | Yes | Yes | Shut down |
3 | Over Load Shut Down Reset | Yes (manual) | Yes (manual) | Yes (manual) | Yes (manual) | Yes (manual) | Toggle Button |
4 | Battery Low Alarm per battery | Yes | Yes | Yes | Yes | Yes | Display & LED |
5 | Battery Low Protection per battery | Yes | Yes | Yes | Yes | Yes | Shut down |
6 | Battery Low Shut Down Reset | Yes (manual) | Yes (manual) | Yes (manual) | Yes (manual) | Yes (manual) | Toggle Button |
7 | Over Temperature Alarm | Yes | Yes | Yes | Yes | Yes | Display |
8 | Over Temperature Protection | Yes | Yes | Yes | Yes | Yes | Shut down |
9 | Short Ckts (Mains Mode) | AC Fuse Trip | AC Fuse Trip | AC Fuse Trip | AC Fuse Trip | AC Fuse Trip | External access |
10 | Short Ckts Protection (batteryn Mode) | Yes | Yes | Yes | Yes | Yes | Display |
11 | Short Ckts Retry (battery Mode) | Yes | Yes | Yes | Yes | Yes | Auto |
12 | Short Ckt Reset | Yes | Yes | Yes | Yes | Yes | Toggle Button |
13 | PV Reverse Protection | Yes | Yes | Yes | Yes | Yes | Display |
14 | Mains MCB Trip/Fuse Trip | Yes | Yes | Yes | Yes | Yes | External access |
15 | No Load Shut Down | Yes | Yes | Yes | Yes | Yes | Optional |
(G) | Other Parameters | ||||||
1 | Max. PV Voltage (Voc) | 25 | 25 | 25 | 45 | 45 | V |
2 | Max. PV Current (Isc) | 15 | 15 | 15 | 23 | 23 | A |
3 | Galvanic Isolation through Cu Transformer | Yes | Yes | Yes | Yes | Yes | Provided |
4 | Inverter Type Pure Sine Wave | Yes | Yes | Yes | Yes | Yes | Provided |
5 | Output Load is as per 0.8Pf | 520 | 680 | 800 | 1160 | 1600 | W |
6 | Priority Level (PV – Batt – Grid) Settable | Yes | Yes | Yes | Yes | Yes | Provided |
7 | Battery Under / Over Voltage protection | Yes | Yes | Yes | Yes | Yes | Provided |
8 | Battery & PV Reverse | Yes | Yes | Yes | Yes | Yes | Provided |
9 | AC Over / Under Voltage | Yes | Yes | Yes | Yes | Yes | Provided |
10 | PV kW, kWh to be displayed on display | Yes | Yes | Yes | Yes | Yes | Provided |
11 | Active Faults to be displayed on display | Yes | Yes | Yes | Yes | Yes | Provided |
12 | Battery Status to be displayed on display | Yes | Yes | Yes | Yes | Yes | Provided |
13 | All relevant V, I, P to be displayed | Yes | Yes | Yes | Yes | Yes | Provided |
14 | Ingrus Protection | IP21 | IP21 | IP21 | IP21 | IP21 | or better |
15 | Housing | Powder coated | Powder coated | Powder coated | Powder coated | Powder coated | with bazel |
16 | Cooling | forced / natural | forced / natural | forced / natural | forced / natural | forced / natural | Provided |
17 | Operational Temperature | -10 to +55 | -10 to +55 | -10 to +55 | -10 to +55 | -10 to +55 | deg celcius |
18 | Relative Humidity | 0 to 98 | 0 to 98 | 0 to 98 | 0 to 98 | 0 to 98 | % |
19 | Mounting Arrangement | Wall / Floor / table | Wall / Floor / table | Wall / Floor / table | Wall / Floor / table | Wall / Floor / table | Provided |
20 | Inverter Low voltage disconnect | 10.8 ± 0.2 | 10.8 ± 0.2 | 10.8 ± 0.2 | 10.8 ± 0.2 | 10.8 ± 0.2 | V |
21 | Audible noise produce by inverter | <60 db @ 2 Miter | <60 db @ 2 Miter | <60 db @ 2 Miter | <60 db @ 2 Miter | <60 db @ 2 Miter | Provided |
22 | THD @ full load | < 5 | < 5 | < 5 | < 5 | < 5 | % |